About this product
With its integrated non-contact voltage detection and AutoV/LoZ function preventing false readings caused by ghost voltage, the Fluke 117 Electrician's Multimeter is the perfect multimeter for electricians.
The Fluke 117 provides Min/Max/Average readings, measuring frequency and capacitance.
Specifications
- Maximum Voltage Between any Terminal and Earth Ground: 600 V
- Surge Protection: 6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2
- Fuse for A Input: 11 A, 1000 V FAST Fuse (Fluke PN 803293)
- Display: Digital: 6,000 counts, updates 4 per second
- Bar Graph: 33 segments, updates 32 per second
- Operating Temperature: -10°C to +50°C
- Storage Temperature: -40°C to +60°C
- Battery Type: 9 volt Alkaline, NEDA 1604A / IEC 6LR61
- Battery Life: 400 hours typical, without backlight
- DC millivolts
- Range/resolution: 600.0 mV / 0.1 mV
- Accuracy: ±([% of reading] + [counts]): 0.5% + 2
- DC volts
- Range/resolution: 6.000 V / 0.001 V, 60.00 V / 0.01 V, 600.00 V / 0.1 V
- Accuracy: ±([% of reading] + [counts]): 0.5% + 2
- Auto volts
- Range/resolution: 600.0 V / 0.1 V
- Accuracy: 2.0% + 3 (DC, 45 Hz to 500 Hz)
- 4.0% + 3 (500 Hz to 1 kHz)
- AC millivolts¹ True RMS: Range/resolution: 600.0 mV / 0.1 mV
- Accuracy: 1.0% + 3 (DC, 45 Hz to 500 Hz), 2.0% + 3 (500 Hz to 1 kHz)
- AC volts¹ True RMS
- Range/resolution: 6.000 V / 0.001 V, 60.00 V / 0.01 V, 600.0 V / 0.1 V
- Accuracy: 1.0% + 3 (DC, 45 Hz to 500 Hz), 2.0% + 3 (500 Hz to 1 kHz)
- Continuity
- Range/resolution: 600 Ω / 1 Ω
- Accuracy: Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer.
- Ohms
- Range/resolution: 600.0 Ω / 0.1 Ω, 6.000 kΩ / 0.001 kΩ, 60.00 kΩ / 0.01 kΩ, 600.0 kΩ / 0.1 kΩ, 6.000 MΩ / 0.001 MΩ
- Accuracy: 0.9% + 1
- Range/resolution: 40.00 MΩ / 0.01 MΩ
- Accuracy: 5% + 2
- Diode Test
- Range/resolution: 2.00 V / 0.001 V
- Accuracy: 0.9% + 2
- Range/resolution: 1000 nF / 1 nF, 10.00 μF / 0.01 μF, 100.0 μF / 0.1 μF, 9999 μF / 1 μF, 100 μF to 1000 μF
- Accuracy: 1.9% + 2
- Range/resolution: > 1000 μF
- Accuracy: 5% + 20%
- Lo-Z capacitance
- Range: 1 nF to 500 μF
- Accuracy: 10% + 2 typical
- AC amps True RMS (45 Hz to 500 Hz): Range/resolution: 6.000 A / 0.001 A
- 10.00 A / 0.01 A
- Accuracy: 1.5% + 3
- 20 A continuous overload for 30 seconds max
- DC amps: Range/resolution
- 6.000 A / 0.001 A 10.00 A / 0.01 A
- Accuracy: 1.0% + 3
- 20 A continuous overload for 30 seconds max
- Hz (V or A input)²
- Range/resolution: 99.99 Hz / 0.01 Hz, 999.99 Hz / 0.1 Hz, 9.999 Hz / 0.001 Hz, 50.00 Hz / 0.01 Hz
- Accuracy: 0.1% + 2