About this product
The Fluke 115 True RMS digital multi-meter has a compact design and ease to use, it provides the perfect answer for general purpose electrical and electronic test requirements. The Fluke 115 displays True RMS voltage and current readings with 600 count resolution, continuity and capacitance, making it ideal for quick verification's and field service use.
Fluke 115 Digital Multi-meters are independently tested for safe use in CAT III 600V Environments.
Specifications
- Maximum voltage between any terminal and earth ground: 600 V
- Surge protection: 6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2
- Digital Display: 6,000 counts, updates 4 per second
- Bar graph: 33 segments, updates 32 per second
- Operating Temperature: -10°C to + 50°C
- Storage Temperature: -40°C to + 60°C
- Battery Type: 9 volt Alkaline, NEDA 1604A / IEC 6LR61
- Battery Life: 400 hours typical, without backlight
- DC millivolts
- Range / Resolution: 600.0 mV / 0.1 mV
- Accuracy: ± ([% of reading] + [counts]): 0.5% + 2
- DC volts
- Range / Resolution: 6.000 V / 0.001, V60.00 V / 0.01, V600.00 V / 0.1 V
- Accuracy: ± ([% of reading] + [counts]): 0.5% + 2
- AC millivolts1 True RMS
- Range / Resolution: 600.0 mV / 0.1 mV
- Accuracy: 1.0% + 3 (DC, 45 Hz to 500 Hz)
- 2.0% + 3 (500 Hz to 1 kHz)
- AC volts1 True RMS
- Range / Resolution: 6.000 V / 0.001 V, 60.00 V / 0.01 V, 600.0 V / 0.1 V
- Accuracy: 1.0% + 3 (DC, 45 Hz to 500 Hz)
- 2.0% + 3 (500 Hz to 1 kHz)
- Continuity
- Range / Resolution: 600 Ω / 1 Ω
- Accuracy: Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer.
- Ohms
- Range /Resolution: 600.0 Ω / 0.1 Ω, 6.000 kΩ / 0.001 kΩ, 60.00 kΩ / 0.01 kΩ, 600.0 kΩ / 0.1 kΩ, 6.000 MΩ / 0.001 MΩ
- Accuracy: 0.9% + 1
- Range / Resolution: 40.00 MΩ / 0.01 MΩ
- Accuracy: 5% + 2
- Diode test
- Range / Resolution: 2.00 V / 0.001 V
- Accuracy: 0.9% + 2
- Capacitance
- Range / Resolution: 1000 nF / 1 nF, 10.00 μF / 0.01 μF, 100.0 μF / 0.1 μF, 9999 μF / 1 μF, 100 μF to 1000 μF
- Accuracy: 1.9% + 2
- Range / Resolution > 1000 μF
- Accuracy: 5% + 20%
- Lo-Z capacitance
- Range: 1 nF to 500 μF
- Accuracy: 10% + 2 typical
- AC amps True RMS
- (45 Hz to 500Hz)
- Range/resolution: 6.000 A / 0.001 A, 10.00 A / 0.01 A
- Accuracy 1.5% + 3
- 20 A overload for 30-seconds max
- DC amps
- Range/resolution: 6.000 A / 0.001 A, 10.00 A / 0.01 A
- Accuracy 1.0% + 3
- Range/resolution: 99.99 Hz / 0.01 Hz, 999.9 Hz / 0.01 Hz, 9.999 kHz / 0.001 kHz, 50 kHz / 0.01 kHz
- Accuracy: 0.1% + 2