Sale

Fluke

General Purpose Digital Multimeter Cat III (600V)

(No reviews yet) Write a Review
$259.87
SKU:
2538790
Adding to cart… The item has been added

Description

The Fluke 115 True RMS digital multi-meter has a compact design and ease to use, it provides the perfect answer for general purpose electrical and electronic test requirements. The Fluke 115 displays True RMS voltage and current readings with 600 count resolution, continuity and capacitance, making it ideal for quick verification's and field service use.



Fluke 115 Digital Multi-meters are independently tested for safe use in CAT III 600V Environments.

Specifications

Maximum voltage between any terminal and earth ground: 600 V

Surge protection: 6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2

Digital Display: 6,000 counts, updates 4 per second

Bar graph: 33 segments, updates 32 per second

Operating Temperature: -10°C to + 50°C

Storage Temperature: -40°C to + 60°C

Battery Type: 9 volt Alkaline, NEDA 1604A / IEC 6LR61

Battery Life: 400 hours typical, without backlight

DC millivolts

Range / Resolution: 600.0 mV / 0.1 mV

Accuracy: ± ([% of reading] + [counts]): 0.5% + 2

DC volts

Range / Resolution: 6.000 V / 0.001, V60.00 V / 0.01, V600.00 V / 0.1 V

Accuracy: ± ([% of reading] + [counts]): 0.5% + 2

AC millivolts1 True RMS

Range / Resolution: 600.0 mV / 0.1 mV

Accuracy: 1.0% + 3 (DC, 45 Hz to 500 Hz)

2.0% + 3 (500 Hz to 1 kHz)

AC volts1 True RMS

Range / Resolution: 6.000 V / 0.001 V, 60.00 V / 0.01 V, 600.0 V / 0.1 V

Accuracy: 1.0% + 3 (DC, 45 Hz to 500 Hz)

2.0% + 3 (500 Hz to 1 kHz)

Continuity

Range / Resolution: 600 Ω / 1 Ω

Accuracy: Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer.

Ohms

Range /Resolution: 600.0 Ω / 0.1 Ω, 6.000 kΩ / 0.001 kΩ, 60.00 kΩ / 0.01 kΩ, 600.0 kΩ / 0.1 kΩ, 6.000 MΩ / 0.001 MΩ

Accuracy: 0.9% + 1

Range / Resolution: 40.00 MΩ / 0.01 MΩ

Accuracy: 5% + 2

Diode test

Range / Resolution: 2.00 V / 0.001 V

Accuracy: 0.9% + 2

Capacitance

Range / Resolution: 1000 nF / 1 nF, 10.00 μF / 0.01 μF, 100.0 μF / 0.1 μF, 9999 μF / 1 μF, 100 μF to 1000 μF

Accuracy: 1.9% + 2

Range / Resolution > 1000 μF

Accuracy: 5% + 20%

Lo-Z capacitance

Range: 1 nF to 500 μF

Accuracy: 10% + 2 typical

AC amps True RMS

(45 Hz to 500Hz)

Range/resolution: 6.000 A / 0.001 A, 10.00 A / 0.01 A

Accuracy 1.5% + 3

20 A overload for 30-seconds max

DC amps

Range/resolution: 6.000 A / 0.001 A, 10.00 A / 0.01 A

Accuracy 1.0% + 3

Range/resolution: 99.99 Hz / 0.01 Hz, 999.9 Hz / 0.01 Hz, 9.999 kHz / 0.001 kHz, 50 kHz / 0.01 kHz

Accuracy: 0.1% + 2

Recommended Products