Description
The Fluke 373 Clamp Meter provides improved performance perfect for any AC only current measurement situations. Featuring True RMS AC voltage and current measurements, and resistance measurement up to 6000 Ω with continuity detection.
Range: 600.0 A
Resolution: 0.1 A
Accuracy: 2 % ± 5 digits (48 – 62 Hz)
Crest Factor: (50/60 Hz) 2.5 @ 600 A
AC Voltage
Range: 600.0 V
Resolution: 0.1 V
Accuracy: 1.0 % ± 5 digits (48 – 62 Hz)
DC Voltage
Range: 600.0 V
Resolution: 0.1 V
Accuracy: 1 % ± 5 digits
Resistance
Range: 600.0 Ω/6000 Ω
Resolution: 0.1 Ω/1 Ω
Accuracy: 1 % ± 5 digits
Continuity Beeper: 30 Ω
Capacitance
Range: 10.0 – 100.0 μF / 1000 μF
Resolution: 0.1 μF/1 μF
Accuracy: 1.9 % ± 2 digits
Environmental Specifications
Operating Temperature: -10 °C to +50 °C
Storage Temp: -40 °C to +60 °C
Operating Humidity: Non condensing (< 10 °C) ≤ 90 % RH (at 10 °C to 30 °C) ≤ 75 % RH (at 30 °C to 40 °C) ≤ 45 % RH (at 40 °C to 50 °C) (Without Condensation)
Operating Altitude: 3000 meters
Storage Altitude: 12,000 meters
EMI, EMC: Meets all applicable requirements in EN61326-1:2006
Temperature Coefficients: Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C
Safety Compliance: ANSI/ISA S82.02.01:2004 CAN/CSA-C22.2 No. 61010-1-04 IEC/EN 61010-1:2001, 600V CAT III, 300V CAT IV Pollution Degree 2 EN/IEC 61010-2-32:2002 EN/IEC 61010-031:2002/A1:2008
Batteries: 2 AA, NEDA 15A, IEC LR6
Specifications
AC CurrentRange: 600.0 A
Resolution: 0.1 A
Accuracy: 2 % ± 5 digits (48 – 62 Hz)
Crest Factor: (50/60 Hz) 2.5 @ 600 A
AC Voltage
Range: 600.0 V
Resolution: 0.1 V
Accuracy: 1.0 % ± 5 digits (48 – 62 Hz)
DC Voltage
Range: 600.0 V
Resolution: 0.1 V
Accuracy: 1 % ± 5 digits
Resistance
Range: 600.0 Ω/6000 Ω
Resolution: 0.1 Ω/1 Ω
Accuracy: 1 % ± 5 digits
Continuity Beeper: 30 Ω
Capacitance
Range: 10.0 – 100.0 μF / 1000 μF
Resolution: 0.1 μF/1 μF
Accuracy: 1.9 % ± 2 digits
Environmental Specifications
Operating Temperature: -10 °C to +50 °C
Storage Temp: -40 °C to +60 °C
Operating Humidity: Non condensing (< 10 °C) ≤ 90 % RH (at 10 °C to 30 °C) ≤ 75 % RH (at 30 °C to 40 °C) ≤ 45 % RH (at 40 °C to 50 °C) (Without Condensation)
Operating Altitude: 3000 meters
Storage Altitude: 12,000 meters
EMI, EMC: Meets all applicable requirements in EN61326-1:2006
Temperature Coefficients: Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C
Safety Compliance: ANSI/ISA S82.02.01:2004 CAN/CSA-C22.2 No. 61010-1-04 IEC/EN 61010-1:2001, 600V CAT III, 300V CAT IV Pollution Degree 2 EN/IEC 61010-2-32:2002 EN/IEC 61010-031:2002/A1:2008
Batteries: 2 AA, NEDA 15A, IEC LR6