Description
Amprobe 30XR-A Digital Multimeter is for non-contact voltage testing, offering Voltect non-contact voltage technology built into the 30XR-A along with a full complement of measurement functions.
DC Voltage accuracy: all ranges: ± (1 % rdg + 1 dgt)
DC Voltage resolution: 100 µV
DC Voltage input impedance: 10 MO
AC Voltage (45 Hz to 500 Hz) ranges: 200 mV, 2 V, 20 V, 200 V, 600 V
AC Voltage (45 Hz to 500 Hz) accuracy: all ranges: ± (1.5 % rdg + 4 dgts)
AC Voltage (45 Hz to 500 Hz) resolution: 100 µV
AC Voltage (45 Hz to 500 Hz) input impedance: 10 MO
DC Current ranges: 200 µA, 2 mA, 20 mA, 200 mA, 10 A
DC Current accuracy: 200 µA to 200 mA ranges: ± (1.5 % rdg + 1 dgt)
DC Current accuracy: 10 A range: ± (2.0 % rdg + 3 dgts)
DC Current resolution: 0.1 µA
DC Current voltage burden (max): 200 µA range: 1 mV/µA
DC Current voltage burden (max): 2 mA range: 100 mV/1mA
DC Current voltage burden (max): 20 mA range: 13 mV/1 mA
DC Current voltage burden (max): 200 mA range: 4.6 mV/1 mA
DC Current voltage burden (max): 10A range: 40 mV/1 A
AC Current (45 Hz to 500 Hz) ranges: 200 µA, 2 mA, 20 mA, 200 mA, 10 A
AC Current (45 Hz to 500 Hz) accuracy: 200 µA to 200 mA ranges: ± (2.0 % rdg + 4 dgts)
AC Current (45 Hz to 500 Hz) accuracy: 10A range: ± (2.5 % rdg + 4 dgts)
AC Current resolution: 0.1 µA
AC Current voltage burden: See DC Current
Non-contact voltage detector (NCV) AC volts: 70 to 600 V ac
Non-contact voltage detector (NCV): Red LED and Audible Indicator
DC Voltage: 200.0 mV 2.000 V, 20.00 V, 200.0 V, 500 V
AC Voltage: 200.0 mV 2.000 V, 20.00 V, 200.0 V, 500 V
DC Current: 200.0 µA 2.000 mA, 20.00 mA, 200.0 mA, 10 A
AC Current: 200.0 µA 2.000 mA, 20.00 mA, 200.0 mA, 10 A
Resistance: 200.0 O, 2.000 kO, 20.00 kO, 200.0 kO, 2.000 MO, 20.00 MO
Included Accessories: Test leads (TL36A), 9 V battery (installed), Magne-Grip Holster with magnetic hanging strap, spare fuse, user manual
Specifications
DC Voltage ranges: 200 mV, 2 V, 20 V, 200 V, 600 VDC Voltage accuracy: all ranges: ± (1 % rdg + 1 dgt)
DC Voltage resolution: 100 µV
DC Voltage input impedance: 10 MO
AC Voltage (45 Hz to 500 Hz) ranges: 200 mV, 2 V, 20 V, 200 V, 600 V
AC Voltage (45 Hz to 500 Hz) accuracy: all ranges: ± (1.5 % rdg + 4 dgts)
AC Voltage (45 Hz to 500 Hz) resolution: 100 µV
AC Voltage (45 Hz to 500 Hz) input impedance: 10 MO
DC Current ranges: 200 µA, 2 mA, 20 mA, 200 mA, 10 A
DC Current accuracy: 200 µA to 200 mA ranges: ± (1.5 % rdg + 1 dgt)
DC Current accuracy: 10 A range: ± (2.0 % rdg + 3 dgts)
DC Current resolution: 0.1 µA
DC Current voltage burden (max): 200 µA range: 1 mV/µA
DC Current voltage burden (max): 2 mA range: 100 mV/1mA
DC Current voltage burden (max): 20 mA range: 13 mV/1 mA
DC Current voltage burden (max): 200 mA range: 4.6 mV/1 mA
DC Current voltage burden (max): 10A range: 40 mV/1 A
AC Current (45 Hz to 500 Hz) ranges: 200 µA, 2 mA, 20 mA, 200 mA, 10 A
AC Current (45 Hz to 500 Hz) accuracy: 200 µA to 200 mA ranges: ± (2.0 % rdg + 4 dgts)
AC Current (45 Hz to 500 Hz) accuracy: 10A range: ± (2.5 % rdg + 4 dgts)
AC Current resolution: 0.1 µA
AC Current voltage burden: See DC Current
Non-contact voltage detector (NCV) AC volts: 70 to 600 V ac
Non-contact voltage detector (NCV): Red LED and Audible Indicator
DC Voltage: 200.0 mV 2.000 V, 20.00 V, 200.0 V, 500 V
AC Voltage: 200.0 mV 2.000 V, 20.00 V, 200.0 V, 500 V
DC Current: 200.0 µA 2.000 mA, 20.00 mA, 200.0 mA, 10 A
AC Current: 200.0 µA 2.000 mA, 20.00 mA, 200.0 mA, 10 A
Resistance: 200.0 O, 2.000 kO, 20.00 kO, 200.0 kO, 2.000 MO, 20.00 MO
Included Accessories: Test leads (TL36A), 9 V battery (installed), Magne-Grip Holster with magnetic hanging strap, spare fuse, user manual