Description
Perfect for easy one-hand operation, the Fluke 114 True RMS digital multi-meter is an ideal troubleshooting tool for go/no go testing. Its AutoVolt capability automatically switches to measure AC or DC voltage, whichever is present. The LoZ function helps identify so-called ghost voltage and prevent false readings.
The Fluke 114 displays true-rms voltage and current readings with 6000 count resolution, and tests frequency, continuity and resistance. The large white LED backlight display aids work in poorly lit areas. Changing batteries is easy with Its easy-open battery access.
Fluke 114 multi-meters are independently tested for safe use in CAT III 600V environments.
Surge protection: 6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2
Digital Display: 6,000 counts, updates 4 per second
Bar graph: 33 segments, updates 32 per second
Operating temperature: -10°C to + 50°C
Storage temperature: -40°C to + 60°C
Battery type: 9 volt Alkaline, NEDA 1604A / IEC 6LR61
Battery life: 400 hours typical, without backlight
DC millivolts
Range/resolution: 600.0 mV / 0.1 mV
Accuracy: ± ([% of reading] + [counts]): 0.5% + 2
DC volts
Range/resolution: 6.000 V / 0.001, V60.00 V / 0.01, V600.00 V / 0.1 V
Accuracy: ± ([% of reading] + [counts]): 0.5% + 2
Auto volts
Range/resolution: 600.0 V / 0.1 V
Accuracy: 2.0% + 3 (DC, 45 Hz to 500 Hz) 4.0% + 3 (500 Hz to 1 kHz)
AC millivolts1 True RMS: Range/resolution: 600.0 mV / 0.1 mV
Accuracy: 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz)
AC volts1 True RMS
Range/resolution: 6.000 V / 0.001, V60.00 V / 0.01, V600.0 V / 0.1 V
Accuracy: 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz)
Continuity
Range/resolution: 600 Ω / 1 Ω
Accuracy: Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer.
Ohms
Range/resolution: 600.0 Ω / 0.1 Ω, 6.000 kΩ / 0.001 kΩ, 60.00 kΩ / 0.01 kΩ, 600.0 kΩ / 0.1 kΩ, 6.000 MΩ / 0.001 MΩ
Accuracy: 0.9% + 1
Range / Resolution: 40.00 MΩ / 0.01 MΩ
Accuracy: 5% + 2
The Fluke 114 displays true-rms voltage and current readings with 6000 count resolution, and tests frequency, continuity and resistance. The large white LED backlight display aids work in poorly lit areas. Changing batteries is easy with Its easy-open battery access.
Fluke 114 multi-meters are independently tested for safe use in CAT III 600V environments.
Specifications
Maximum voltage between any terminal and earth ground: 600 VSurge protection: 6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2
Digital Display: 6,000 counts, updates 4 per second
Bar graph: 33 segments, updates 32 per second
Operating temperature: -10°C to + 50°C
Storage temperature: -40°C to + 60°C
Battery type: 9 volt Alkaline, NEDA 1604A / IEC 6LR61
Battery life: 400 hours typical, without backlight
DC millivolts
Range/resolution: 600.0 mV / 0.1 mV
Accuracy: ± ([% of reading] + [counts]): 0.5% + 2
DC volts
Range/resolution: 6.000 V / 0.001, V60.00 V / 0.01, V600.00 V / 0.1 V
Accuracy: ± ([% of reading] + [counts]): 0.5% + 2
Auto volts
Range/resolution: 600.0 V / 0.1 V
Accuracy: 2.0% + 3 (DC, 45 Hz to 500 Hz) 4.0% + 3 (500 Hz to 1 kHz)
AC millivolts1 True RMS: Range/resolution: 600.0 mV / 0.1 mV
Accuracy: 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz)
AC volts1 True RMS
Range/resolution: 6.000 V / 0.001, V60.00 V / 0.01, V600.0 V / 0.1 V
Accuracy: 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz)
Continuity
Range/resolution: 600 Ω / 1 Ω
Accuracy: Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer.
Ohms
Range/resolution: 600.0 Ω / 0.1 Ω, 6.000 kΩ / 0.001 kΩ, 60.00 kΩ / 0.01 kΩ, 600.0 kΩ / 0.1 kΩ, 6.000 MΩ / 0.001 MΩ
Accuracy: 0.9% + 1
Range / Resolution: 40.00 MΩ / 0.01 MΩ
Accuracy: 5% + 2